Filters
Modification of glassy carbon electrode by the electrochemical oxidation of 3-aminophenylcalix[4]pyrrole in nonaqueous media

Ali Osman SOLAK

Article | 2012 | Surface and Interface Analysis44 ( 2 )

3-Aminophenylcalix[4]pyrrole (3APCP) was grafted to a glassy carbon (GC) surface during the electrochemical oxidation process in 0.1 M tetrabutylammoniumtetra-fluoroborate (TBATFB) containing acetonitrile solution. The presence of a surface film was confirmed electrochemically by comparing voltammograms of dopamine and ferricyanide redox probes at the bare and modified electrodes. Reflection-absorption infrared spectroscopy (RAIRS), XPS, atomic force microscopy (AFM), ellipsometry and the contact angle measurements were also employed to characterize 3APCP film on GC electrode. RAIRS analysis revealed that calix[4]pyrrole was bonded . . .to the glassy carbon surface via the etheric linkage. The stability of the modified GC electrode was also studied. Copyright © 2011 John Wiley & Sons, Ltd More less

Synthesis, characterization, and application of silver nanoparticle-thiophenol nanocomposite film on the glassy carbon surface

Ali Osman SOLAK

Article | 2013 | Surface and Interface Analysis45 ( 13 )

In this study, 4-thiophenol modified glassy carbon electrode was prepared by the reduction of 4-diazothiophenol tetrafluoroborate salt. Silver nanoparticles were attached to the thiophenol modified surface to prepare a thiophenol-silver nanoparticle composite film. 4-Aminothiopenol molecules were deposited by self-assembling technique to form multi-layered nanofilms of TP/SNP/PhNH2 on glassy carbon substrate. These surfaces were characterized by cyclic voltammetry, electrochemical impedance spectroscopy, X-ray photoelectron spectroscopy, reflectance-absorption infrared spectroscopy, and ellipsometry at each multilayer film growth pr . . .ocess. Atomic force microscopic images of GC/TP/SNP/PhNH2 surfaces were also acquired. The characterization methods show that the amine group containing surface permits the subsequent modification by a variety of coupling reactions for the immobilization of more complex systems. An application of the electrode modification for the determination of uric acid with a significantly lower detection limit is described More less

Our obligations and policy regarding cookies are subject to the TR Law on the Protection of Personal Data No. 6698.
OK

creativecommons
Bu site altında yer alan tüm kaynaklar Creative Commons Alıntı-GayriTicari-Türetilemez 4.0 Uluslararası Lisansı ile lisanslanmıştır.
Platforms